Single core medium voltage cables
|
Supply Ability: |
|
Related proudcts |
single core, medium voltage, |
Specifications |
BS 6622 |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
APPLICATIONS The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations. STANDARD BS 6622BS 7835 (LSZH Version) CONSTRUCTION Conductor Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2). Conductor Screen Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C. Insulation Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.
Insulaton Screen Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. Metallic Layer The metallic layer shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path, capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, cop |
Company: |
caledonian cables ltd
|
Contact: |
Ms. Rainbow Miao |
Address: |
Room3501,CITIC Square, 1168,Nanjing Xi Lu, Shanghai, |
Postcode: |
200000 |
Tel: |
86-21-62860355 |
Fax: |
86-21-52524616 |
E-mail: |
|
|
|
|